1.
Braz. j. pharm. sci ; 51(4): 803-810, Oct.-Dec. 2015. tab, graf
Article in English | LILACS | ID: lil-778417

ABSTRACT

abstract A simple stability-indicating RP-HPLC/UV method was validated for determination of beclomethasone dipropionate (BD) in nanocapsule suspensions. Chromatographic conditions consisted of a RP C18column (250 mm x 4.60 mm, 5 µm, 110 Å), using methanol and water (85:15 v/v) as mobile phase at 1.0 mL/min with UV detection at 254 nm. The calibration curve was found to be linear in the concentration range of 5.0-25.0 µg/mL with a correlation coefficient > 0.999. Precision was demonstrated by a relative standard deviation lower than 2.0%. Accuracy was assessed by the recovery test of BD from nanocapsules (98.03% to 100.35%). Specificity showed no interference from the components of nanocapsules or from the degradation products derived from acid, basic and photolytic conditions. In conclusion, the method is suitable to be applied to assay BD in bulk drug and in nanocapsules, and it can be employed to study stability and degradation kinetics.


resumo Um método simples de CLAE-FR/UV indicativo de estabilidade foi validado para a determinação do dipropionato de beclometasona (BD) em suspensões de nanocápsulas. As condições cromatográficas foram: coluna C18 fase reversa (250 mm x 4,60 mm, 5 µm, 110 Å), usando como fase móvel metanol e água (85:15 v/v) a 1,0 mL/min, com detecção UV a 254 nm. A curva de calibração foi linear no intervalo de 5,0-25,0 µg/mL com coeficiente de correlação >0,999. A precisão foi demonstrada por um desvio padrão relativo menor que 2,0%. A exatidão foi avaliada pelo teste de recuperação do BD a partir das nanocápsulas (98,03% a 100,35%). O teste de especificidade não mostrou interferência dos componentes das nanocápsulas e nem dos produtos de degradação derivados de condições ácidas, básicas e fotolíticas. Em conclusão, o método é adequado para ser aplicado na avaliação do BD puro e em nanocápsulas e pode ser empregado para o estudo de estabilidade e degradação cinética.


Subject(s)
Beclomethasone/pharmacokinetics , Chromatography, High Pressure Liquid/methods , Nanocapsules , Nanoparticles , Chromatography, Reverse-Phase
2.
Braz. j. pharm. sci ; 51(3): 561-567, July-Sept. 2015. tab, graf
Article in English | LILACS | ID: lil-766308

ABSTRACT

Hydroxymethylnitrofurazone (NFOH) is a new compound with potential leishmanicidal and trypanocidal activity. Despite its effectiveness, the formulators have to overcome its poor aqueous solubility. Recently, polymeric nano-scale drug delivery systems have proposed for the treatment of neglected diseases. As several studies have confirmed the advantages of such formulations, and this approach provides new analytical challenges, including the need to detect trace amounts of the drug. A suitable method was developed and validated for NFOH determination bound to poly (n-butylcyanoacrylate) (PBCA) nanoparticles. The chromatographic separation was achieved using a C18 column maintained at 25 ºC and an isocratic mobile phase consisting of water and acetonitrile: 80:20 (v/v) at a flow rate of 1.2 mL min-1 and UV-detection at 265 nm. Investigated validation parameters included selectivity, linearity, accuracy, precision and robustness (changes in column temperature, mobile phase composition and flow). The method was specific, the peak of NFOH had no interference with any nanoparticle excipients and no co-elution with main degradation product (nitrofurazone). Linearity was over the range of 0.94 13.11 μg mL-1 (r2=0.999). The method was accurate and precise, recovery of 100.7%, RSD of 0.4%; intra-day and inter-day RSD range 9.98-9.99 μg mL-1 and 0.3% to 0.5%, respectively. Robustness confirmed that method could resist the applied changes. Application of the optimized method revealed an encapsulation efficiency of 64.4% (n=3). Therefore, the method was successfully developed and validated for the determination of the encapsulation efficiency of NFOH-PBCA nanoparticles.


Hidroximetilnitrofural (NFOH) é um novo composto que possui atividade leishmanicida e tripanomicida potencial. Um método apropriado foi desenvolvido e validado para a determinação de NFOH em nanopartículas de poli(n-butil cianoacrilato) (PBCA). A separação cromatográfica foi obtida usando uma coluna C18 (5 µm de tamanho de partícula, 4,6 mm de diâmetro e 150 mm de comprimento), mantida a 25 °C, fase móvel composta de água e acetonitrila 80:20 (v/v), fluxo de 1,2 mL min- 1 e detecção por UV a 265 nm. Investigaram-se os seguintes parâmetros de validação: seletividade, linearidade, exatidão, precisão e robustez (mudanças na temperatura de coluna, proporção da fase móvel e fluxo). O método mostrou-se específico, o pico de NFOH não apresentou interferência dos picos provenientes dos excipientes das nanopartículas e separado do principal produto de degradação (nitrofural). A linearidade foi obtida na faixa de 0,94-13,11 μg mL- 1 (r2=0,999). O método mostrou exatidão (recuperação de 100,7%, DPR de 0,4 %) e precisão (intra-dia e inter-dia, 9,98-9,99 μg mL- 1 e DPR 0,3% a 0,5%, respectivamente). A robustez provou que o método pode resistir às mudanças propostas. Aplicação do método otimizado revelou eficiência de encapsulação de 64,4% (n=3). Portanto, o método foi desenvolvido e validado com sucesso para a determinação da eficiência de encapsulação de nanopartículas de NFOH-PBCA.


Subject(s)
Chromatography, Liquid/classification , Nanoparticles , Nitrofurazone/pharmacokinetics , Enbucrilate , Chromatography, Reverse-Phase
3.
Braz. j. pharm. sci ; 50(1): 213-223, Jan-Mar/2014. tab, graf
Article in English | LILACS | ID: lil-709545

ABSTRACT

A reversed-phase high performance liquid chromatography method was validated for the determination of cefazolin sodium in lyophilized powder for solution for injection to be applied for quality control in pharmaceutical industry. The liquid chromatography method was conducted on a Zorbax Eclipse Plus C18 column (250 x 4.6 mm, 5 μm), maintained at room temperature. The mobile phase consisted of purified water: acetonitrile (60: 40 v/v), adjusted to pH 8 with triethylamine. The flow rate was of 0.5 mL min-1 and effluents were monitored at 270 nm. The retention time for cefazolin sodium was 3.6 min. The method proved to be linear (r2=0.9999) over the concentration range of 30-80 µg mL-1. The selectivity of the method was proven through degradation studies. The method demonstrated satisfactory results for precision, accuracy, limits of detection and quantitation. The robustness of this method was evaluated using the Plackett–Burman fractional factorial experimental design with a matrix of 15 experiments and the statistical treatment proposed by Youden and Steiner. Finally, the proposed method could be also an advantageous option for the analysis of cefazolin sodium, contributing to improve the quality control and to assure the therapeutic efficacy.


Um método cromatográfico em fase reversa foi validado para a determinação de cefazolina sódica em pó liofilizado, a ser aplicado no controle de qualidade em indústrias farmacêuticas. O método por cromatografia líquida foi conduzido em coluna Zorbax Eclipse Plus C18 (250 × 4,6 mm, 5 µm) mantida à temperatura ambiente. A fase móvel consistiu de água purificada: acetonitrila (60 : 40 v/v), com o pH ajustado para 8 com trietilamina. A vazão usada foi de 0,5 mL min-1 e os analitos de interesse foram monitorizados a 270 nm. O tempo de retenção da cefazolina sódica foi de 3,6 min. As áreas dos picos de cefazolina sódica foram lineares na faixa de concentração de 30-80 µg mL-1 (r2 = 0,9999). A seletividade do método foi demonstrada através de estudos de degradação. O método demonstrou resultados satisfatórios para precisão, exatidão, limites de detecção e de quantificação. A robustez do método foi avaliada utilizando o esquema fatorial de Plackett-Burman com uma matriz de 15 experimentos simultâneos, e analisados por tratamento estatístico proposto por Youden e Steiner. Finalmente, o método proposto pode ser também uma opção de êxito para a análise de cefazolina sódica, contribuindo para o controle de qualidade e para garantir a eficácia terapêutica.


Subject(s)
Cefazolin/analysis , Chromatography, High Pressure Liquid/methods , Quality Control , Drug Industry/trends , Freeze Drying/methods
4.
Braz. j. pharm. sci ; 50(4): 859-868, Oct-Dec/2014. tab, graf
Article in English | LILACS | ID: lil-741365

ABSTRACT

In this work, we developed and validated an effective reversed-phase HPLC method with photodiode array (PDA) detection for the quantitative analysis of amphotericin B (AmB) in poly(lactide)-poly(ethylene glycol) (PLA-PEG) blend nanoparticles. Chromatographic runs were performed on a reverse phase C18 column using a mobile phase comprising a 9% acetic acid and acetonitrile mixture (40:60, v/v) under isocratic elution with a flow rate of 1 mL/min. AmB was detected at a wavelength of 408 nm. The validation process was performed considering the selectivity, linearity, precision, accuracy, robustness, limit of detection (LOD) and limit of quantitation (LOQ) of the method. A concentration range of 1-20 µg/mL was used to construct a linear calibration curve. The LOQ and LOD were 55 and 18 ng/mL, respectively. The mean recovery of AmB from the samples was 99.92% (relative standard deviation (RSD) = 0.34%, n=9), and the method was robust for changes in the flow rate of the mobile phase (maximum RSD=4.82%). The intra- and inter-assay coefficients of variation were less than 0.59%. The method was successfully used to determine the entrapment efficiency of AmB in PLA-PEG blend nanoparticles.


Neste trabalho desenvolveu-se e validou-se um efetivo método por cromatografia líquida de alta eficiência (CLAE) em fase reversa com detecção por fotodiodos para a análise quantitativa de anfotericina B (AmB) em nanopartículas compostas por blendas de poli(ácido lático)-polietilenoglicol (PLA-PEG). Corridas cromatográficas foram realizadas sob coluna C18 de fase reversa com fase móvel consistindo de ácido acético 9% e acetonitrila (40:60, v/v), em eluição isocrática com fluxo de 1 mL/min. A AmB foi detectada no comprimento de onda de 408 nm. O processo de validação foi realizado considerando a seletividade, linearidade, precisão, exatidão, robustez, limite de detecção (LD) e limite de quantificação (LQ) do método. Uma faixa de concentração entre 1-20 µg/mL foi usada para obter a curva-padrão linear. Os valores de LD e LQ foram 55 e 18 ng/mL, respectivamente. A recuperação média da AmB a partir das amostras foi de 99,92% (desvio padrão relativo = 0,34%, n=9) e o método foi robusto, considerando alterações no fluxo da fase móvel (desvio padrão relativo máximo=4,82%). Os coeficientes de variação intra e inter dia foram inferiores a 0,59%. O método foi utilizado com sucesso para a determinação da eficiência de encapsulação da AmB em nanopartículas de PLA-PEG.


Subject(s)
Amphotericin B/analysis , Chromatography, High Pressure Liquid/methods , Nanoparticles/analysis , Amphotericin B/pharmacokinetics , Chromatography, Reverse-Phase